Flame and Furnace AA Atomic Absorption Spectrophotometer with PC and Printer

Brand Name : AI

Model Number : 4530F

Certification : ISO

Place of Origin : China

MOQ : 1 Set Flame and Furnace AA Atomic Absorption Spectrophotometer

Price : Negotiable

Payment Terms : D/P, T/T, L/C, Western Union

Supply Ability : 100 Sets per Month

Delivery Time : 20 days

Packaging Details : Flame and Furnace AA Atomic Absorption Spectrophotometer packed in Plywood case

Test method : Atomic Absorption Spectrophotometer

Wavelength range : 190 ~ 900nm

Grating : 1800 lines/mm

Turrets : 8 Positions

Power supply : 220V±22V AC

Dimension : 700mm×550mm×450mm

Weight : 75KG

Warranty : 1 Year

Contact Now

Atomic Absorption Spectrophotometer

Features:

This atomic absorption spectrophotometer is complete automatic controlling system;

The instrument can be worked with advanced graphite furnace temperature controlling technology;
Safe, reliable and convenient flame system;
Multi-functional software workstation;
This flame system atomic absorption spectrophotometer is ompletely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional);
Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term;
Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp;
Position adjusting: the best height of the flame burner and can automatically set the front and rear positions;
Fully automated wavelength scanning and peak searching;
Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout;
Deuterium lamp and self-absorption background regulation;
Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called;
Measuring method of AAS machine: flame absorption method and emission method;
Result printing: parameter printing, data result printing and diagram printing;

Instrument Configuration:

Atomic Absorption Spectrophotometer 1pc
Air compressor without noise 1pc
PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)
A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)

Specifications:

Wavelength range 190 ~ 900nm
Spectral bandwidth Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
Accuracy of the wavelength ±0.15nm
Receptivity of the wavelength ≤0.04nm
Base line stability ≤0.002A/30min (Cu)
Characteristic viscosity 0.02μg/ml/1% (Cu)
Checking limit 0.004μg/ml (Cu)
Preciseness 0.5%
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp stand Eight lamps
D2 background correction ability When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Size and weight 700mm×550mm×450mm 75Kg
Power source 220V±22V AC


Flame System:

Acetylene air burner 100mm
Nitrous oxide acetylene flame head 50mm
Ignition dynamic baseline drift ≤0.006A/30min
(Cu) Characteristic viscosity ≤0.025μg/ml/1%
Related standard deviation of the accuracy ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety system Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner


Graphite Furnace:

The highest temperature 3000℃
The largest temperature rising speed ≥2000℃/S
Characteristic quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size and weight 550mm×450mm×300mm 65Kg
Safety system Over current protection
Protection Low air pressure alarm, low cooling water flow alarm
Power source and power 220V±22V AC 7000W

Spares Parts of 4530F Atomic Sbsorption Spectrophotometer

Flame and Furnace AA Atomic Absorption Spectrophotometer with PC and PrinterFlame and Furnace AA Atomic Absorption Spectrophotometer with PC and Printer


Product Tags:

Flame Atomic Absorption Spectrophotometer

      

Furnace Atomic Absorption Spectrophotometer

      

AA Spectrophotometer

      
Quality Flame and Furnace AA Atomic Absorption Spectrophotometer with PC and Printer for sale

Flame and Furnace AA Atomic Absorption Spectrophotometer with PC and Printer Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Advanced Instruments Co.,Limited
*Subject:
*Message:
Characters Remaining: (0/3000)